Mapping of the API 610 data sheet for centrifugal pump

latest update: 2018-05-08         

 

Introduction

In this topic the API 610 11th ed. data sheet for centrifugal pump is being mapped to ISO 15926-8 declared objects and templates. This is probably the most extensive data sheet in the process industries. So the code is equally massive, but manageable.

This mapping is done using TIPs - Templates of Information Pattern, explained in http://15926.org/topics/tips-intro/index.htm

Exegesis

NARRATIVE - First of all a narrative must be prepared, detailing in as clear as possible wording, the semantics of the data.

VALUE CELL - The combination of cells of the official API spreadsheet that contain the data to be mapped.

DECLARE RELATED NODE - Extending the narrative by further specifying the nature of the declared object

CLASS, ACTIVITY,or INDIVIDUAL (Actual or Imaginary) - The second character indicates whether the declared object is actual (existing in the real world) or imaginary (existing in a design world).

AUDER - Administrative - A = Add, U = Update, D = Deprecate, E = Erase, R = Reinstate.

ID - Mapping-internal identifier.

TIP TYPE - Name of the TIP used for the mapping of the data. These will be published on-line with all details.

VAR #x - TIP variable with name and value.

 

Procedure

Step 1

Following the standard procedure for mapping we start with the declarations of the pump and all its subtagged components inasmuch for these components information is given. This is information that is implied but not made specific in the data sheet. This leads to:

  

CENTRIFUGAL PUMP API 610, 11th Ed. DATA SHEET PROMPT (approx.)

NARRATIVE

VALUE CELL

DECLARE  RELATED NODE

CLASS, ACTIVITY,or INDIVIDUAL (Actual or Imaginary)

 

AUDER

 

ID

TIP TYPE

VAR #1

VAR #2

VAR #3

VAR #4

VAR #5

VAR #6

Project Identifier of Activity in which this pump participates in the Role of DELIVERABLE SH1-Q18:AE18 Project

AA

 

A

  N001 var_Type tip:DeclarationOfActivity var_Label map(SH1-Q18:AE18) var_EssentialType rdl:RDS9629 var_EntityType dm:Activity var_WorldType dm:ActualIndividual var_EffectiveDate map    
Client Organization that participates in Project in the Role of CONTRACT OWNER SH1-Q14:AE14 Client

AI

 

A

  N002 var_Type tip:DeclarationOfPhysicalObject var_Label map(SH1-Q14:AE14) var_EssentialType rdl:RDS943618371 var_PhysicalObjectType dm:PhysicalObject var_EntityType lci:Organization var_WorldType dm:ActualIndividual var_EffectiveDate map
MANUFACTURER Organization that manufactured the (Actual) pump(s) SH2-H8:T8 Organization

AI

 

A

  N003 var_Type tip:DeclarationOfPhysicalObject var_Label map(SH2-H8:T8) var_EssentialType rdl:RDS4242650 var_PhysicalObjectType dm:PhysicalObject var_EntityType lci:Organization var_WorldType dm:ActualIndividual var_EffectiveDate map
MODEL Manufacturer's product model of which the (Actual) pump(s) is(are) a member (in case of more than one pump: only one such Model Number) SH2-Y8:AB8  Actual Pump(s) 

AI

 

A

  N004 var_Type tip:DeclarationOfPhysicalObject var_Label map(SH2-Y8:AB8) var_EssentialType rdl:RDS327239 var_PhysicalObjectType dm:MaterializedPhysicalObject var_EntityType lci:InanimatePhysicalObject var_WorldType dm:ActualIndividual var_EffectiveDate map
 
Item Tag Identifier of the (Design) pump(s) referred to in this Data Sheet SH1-Q20:AE20 Pump

II

 

A

  N010 var_Type tip:DeclarationOfPhysicalObject var_Label map(SH1-Q20:AE20) var_EssentialType rdl:RDS327239 var_PhysicalObjectType dm:FunctionalPhysicalObject var_EntityType lci:InanimatePhysicalObject var_WorldType lci:ImaginaryIndividual var_EffectiveDate map
API PUMP TYPE Specialization of the pump requirements class(es) with an API 610 pump type (in case of more than one pump one such type) SH3-I5:J5 Pump Requirements Class

C

 

A

  N040 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20}] var_EssentialType rdl:RDS2229884 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20}] for PUMP map(SH1-Q20:AE20) var_EffectiveDate map    
Suction Nozzle --- --- NozzleIn

II

 

A

  N011 var_Type tip:DeclarationOfComponentOfPhysicalObject var_LabelOfWhole map(SH1-Q20:AE20) var_LabelOfPart map{(SH1-Q20:AE20)}{-N1} var_PartEntityType lci:InanimatePhysicalObject var_PartEssentialType rdl:RDS415214 var_Definition SUCTION NOZZLE map[{map(SH1-Q20:AE20)}{-N1}] var_EffectiveDate map
Discharge Nozzle --- --- NozzleOut

II

 

A

  N012 var_Type tip:DeclarationOfComponentOfPhysicalObject var_LabelOfWhole map(SH1-Q20:AE20) var_LabelOfPart map{(SH1-Q20:AE20)}{-N2} var_PartEntityType lci:InanimatePhysicalObject var_PartEssentialType rdl:RDS415214 var_Definition SUCTION NOZZLE map[{map(SH1-Q20:AE20)}{-N2}] var_EffectiveDate map
Location The (Design) SpatialLocation in which the (Design) Pump will be located --- Pump SpatialLocation

II

 

A

  N013 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map{(SH1-Q20:AE20)}{-LOC} var_AuxilliaryEntityType dm:SpatialLocation var_AuxilliaryEssentialType rdl:RDS7151497 var_EffectiveDate map    
UNIT Process Unit of which the pump(s) is(are) a part SH2-Y5:AL5 Process Unit

II

 

A

  N014 var_Type tip:DeclarationOfPhysicalObject var_Label map(SH2-Y5:AL5) var_EssentialType rdl:RDS2229214 var_PhysicalObjectType dm:FunctionalPhysicalObject var_EntityType lci:InanimatePhysicalObject var_WorldType lci:ImaginaryIndividual var_EffectiveDate map
SITE Spatial location where the UNIT is located SH2-F6:T6 Site SpatialLocation

II

 

A

  N015 var_Type tip:DeclarationOfPhysicalObject var_Label map(SH2-F6:T6) var_EssentialType rdl:RDS7151859 var_PhysicalObjectType dm:FunctionalPhysicalObject var_EntityType lci:InanimatePhysicalObject var_WorldType lci:ImaginaryIndividual var_EffectiveDate map
LIQUID TYPE OR NAME Stream that is to be pumped --- Stream

II

 

A

  N016 var_Type tip:DeclarationOfContainedPhysicalObject var_LabelOfContainer map(SH1-Q20:AE20) var_LabelOfContained map[{map(SH1-Q20:AE20)}{-S}] var_ContainedEntityType dm:Stream var_ContainedEssentialType rdl:RDS427094 var_EffectiveDate map    
LIQUID TYPE OR NAME Stream requirements class SH2-K12:S12 Stream Class

C

 

A

  N042 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20}{-S}] var_EssentialType rdl:RDS2227031 var_EntityType lci:ClassOfStream var_Definition LIQUID STREAM map[{CO_}{map(SH1-Q20:AE20}{-S}] through PUMP map(SH1-Q20:AE20) var_EffectiveDate map    
LIQUID TYPE OR NAME Stream at suction nozzle --- StreamIn 

II

 

A

  N017 var_Type tip:DeclarationOfContainedPhysicalObject var_LabelOfContainer map[{map(SH1-Q20:AE20)}{-IN}] var_LabelOfContained map[{map(SH1-Q20:AE20)}{-S-IN}] var_ContainedEntityType dm:Stream var_ContainedEssentialType rdl:RDS427094 var_EffectiveDate map    
LIQUID TYPE OR NAME Stream requirements class at suction nozzle SH2-K12:S12 StreamIn Class

C

 

A

  N043 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20}{-S-IN}] var_EssentialType rdl:RDS2227031 var_EntityType lci:ClassOfStream var_Definition LIQUID STREAM map[{CO_}{map(SH1-Q20:AE20}{-S-IN}] through PUMP SUCTION NOZZLE map[{CO_}{map(SH1-Q20:AE20}{-S-IN}] var_EffectiveDate map    
LIQUID TYPE OR NAME Stream at discharge nozzle --- StreamOut

II

 

A

  N018 var_Type tip:DeclarationOfContainedPhysicalObject var_LabelOfContainer map[{map(SH1-Q20:AE20)}{-OUT}] var_LabelOfContained map[{map(SH1-Q20:AE20)}{-S-OUT}] var_ContainedEntityType dm:Stream var_ContainedEssentialType rdl:RDS427094 var_EffectiveDate map    
LIQUID TYPE OR NAME Stream requirements class at discharge nozzle SH2-K12:S12 StreamOut Class

C

 

A

  N044 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20}{-S-OUT}] var_EssentialType rdl:RDS2227031 var_EntityType lci:ClassOfStream var_Definition LIQUID STREAM map[{CO_}{map(SH1-Q20:AE20}{-S-OUT}] through PUMP DISCHARGE NOZZLE map[{CO_}{map(SH1-Q20:AE20}{-S-OUT}] var_EffectiveDate map    
ELECTRICITY FOR DRIVERS  Electrical energy to be made available for motor(s), if applicable --- Electricity1

II

 

A

  N019 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map[{map(SH1-Q20:AE20)}{-ELDRIV}] var_AuxilliaryEntityType rdl:RDS316439 var_AuxilliaryEssentialType rdl:RDS316439 var_EffectiveDate map    
ELECTRICITY FOR DRIVERS  Requirements Class for Electrical energy to be made available for motor(s), if applicable   Class of Electricity1

C

 

A

  N019C var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map[{map(SH1-Q20:AE20)}{-ELDRIV}] var_EssentialType rdl:RDS316439 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS for map[{map(SH1-Q20:AE20)}{-ELDRIV}] var_EffectiveDate map    
ELECTRICITY FOR HEATING  Electrical energy to be made available for heater(s), if applicable --- Electricity2 

II

 

A

  N020 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map[{map(SH1-Q20:AE20)}{-ELHEAT}] var_AuxilliaryEntityType rdl:RDS316439 var_AuxilliaryEssentialType rdl:RDS316439 var_EffectiveDate map    
ELECTRICITY FOR HEATING  Requirements Class for Electrical energy to be made available for heater(s), if applicable   Class of Electricity2 

C

 

A

  N020C var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map[{map(SH1-Q20:AE20)}{-ELHEAT}] var_EssentialType rdl:RDS316439 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS for map[{CO_}{map(SH1-Q20:AE20)  var_EffectiveDate map    
ELECTRICITY FOR CONTROL Electrical energy to be made available for controls, if applicable --- Electricity3

II

 

A

  N021 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map[{map(SH1-Q20:AE20)}{-ELCTRL}] var_AuxilliaryEntityType rdl:RDS316439 var_AuxilliaryEssentialType rdl:RDS316439 var_EffectiveDate map    
ELECTRICITY FOR CONTROL Requirements Class for Electrical energy to be made available for controls, if applicable   Class of Electricity3

C

 

A

  N021C var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map[{map(SH1-Q20:AE20)}{-ELCTRL}] var_EssentialType rdl:RDS316439 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS for map[{map(SH1-Q20:AE20)}{-ELCTRL}] var_EffectiveDate map    
ELECTRICITY FOR SHUTDOWN Electrical energy to be made available for shutdown system, if applicable --- Electricity4

II

 

A

  N022 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map[{map(SH1-Q20:AE20)}{-ELESD}] var_AuxilliaryEntityType rdl:RDS316439 var_AuxilliaryEssentialType rdl:RDS316439 var_EffectiveDate map    
ELECTRICITY FOR SHUTDOWN Requirements Class for Electrical energy to be made available for shutdown system, if applicable   Class of Electricity4

C

 

A

  N022C var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map[{map(SH1-Q20:AE20)}{-ELESD}] var_EssentialType rdl:RDS316439 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS for map[{map(SH1-Q20:AE20)}{-ELESD}] var_EffectiveDate map    
COOLING WATER Cooling water to be made available, if applicable --- Design Stream3

II

 

A

  N023 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map[{map(SH1-Q20:AE20)}{-CW}] var_AuxilliaryEntityType lci:InanimatePhysicalObject var_AuxilliaryEssentialType rdl:RDS1012769 var_EffectiveDate map    
COOLING WATER Requirements Class for Cooling water to be made available, if applicable   Class of Design Stream3

C

 

A

  N023C var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20) var_EssentialType rdl:RDS1012769 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS for map[{map(SH1-Q20:AE20)}{-CW}] var_EffectiveDate map    
INSTRUMENT AIR Instrument air to be made available, if applicable --- Design Stream4

II

 

A

  N024 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map[{map(SH1-Q20:AE20)}{-INAIR}] var_AuxilliaryEntityType lci:InanimatePhysicalObject var_AuxilliaryEssentialType rdl:RDS423764 var_EffectiveDate map    
INSTRUMENT AIR Requirements Class for Instrument air to be made available, if applicable   Class of Design Stream4

C

 

A

  N024C var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20) var_EssentialType rdl:RDS423764 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS for map[{map(SH1-Q20:AE20)}{-INAIR}] var_EffectiveDate map    
STEAM FOR DRIVERS Steam to be made available for turbine(s), if applicable --- Design Stream5

II

 

A

  N025 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map[{map(SH1-Q20:AE20)}{-STMDR}] var_AuxilliaryEntityType lci:InanimatePhysicalObject var_AuxilliaryEssentialType rdl:RDS14208634 var_EffectiveDate map    
STEAM FOR DRIVERS Requirements Class for Steam to be made available for turbine(s), if applicable   Class of Design Stream5

C

 

A

  N025C var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20) var_EssentialType rdl:RDS14208634 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS for map[{map(SH1-Q20:AE20)}{-STMDR}] var_EffectiveDate map    
STEAM FOR HEATING Steam to be made available for heater(s), if applicable --- Design Stream6

II

 

A

  N026 var_Type tip:DeclarationOfAuxilliaryPhysicalObject var_LabelOfMainObject map(SH1-Q20:AE20) var_LabelOfAuxilliary map[{map(SH1-Q20:AE20)}{-STMHT}] var_AuxilliaryEntityType lci:InanimatePhysicalObject var_AuxilliaryEssentialType rdl:RDS14208634 var_EffectiveDate map    
STEAM FOR HEATING Requirements Class for Steam to be made available for heater(s), if applicable   Class of Design Stream6

C

 

A

  N026C var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20) var_EssentialType rdl:RDS14208634 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition REQUIREMENTS CLASS for map[{map(SH1-Q20:AE20)}{-STMHT}] var_EffectiveDate map    
 
Document Number Ur Identifier of this data sheet, exclusive of a revision number SH1-AC72:AL72 Data Sheet

C

 

A

  N030 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map(SH1-AC72:AL72) var_EssentialType api:RDS17986949 var_EntityType dm:ClassOfInformationObject var_Definition UR DATA SHEET  map(SH1-AC72:AL72) for PUMP map(SH1-Q20:AE20). var_EffectiveDate map    
Document Revision Number Ur Identifier + Revision Number of this data sheet. SH1-B68:C68 Data Sheet Rev

C

 

A

  N031 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{map(SH1-AC72:AL72)}{map(SH1-B68:C68)] var_EssentialType api:RDS17986949 var_EntityType dm:ClassOfInformationObject var_Definition DATA SHEET map(SH1-AC72:AL72) REVISION map(SH1-B68:C68) for PUMP map(SH1-Q20:AE20) var_EffectiveDate map    
Inquiry Number Ur Identifier of the ClassOfInformationObject that describes the requirements for the pump, for the most via this data sheet SH1-Q26:W26 Inquiry

C

 

A

  N032 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map(SH1-Q26:W26) var_EssentialType rdl:RDS2229883 var_EntityType dm:ClassOfInformationObject var_Definition UR INQUIRY map(SH1-Q26:W26) for PUMP map(SH1-Q20:AE20) var_EffectiveDate map    
PO Number Ur Identifier of the ClassOfInformatinObject that regulates the delivery of the pump SH1-Q28:AE28 Purchase Order

C

 

A

  N033 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map(SH1-Q28:AE28) var_EssentialType rdl:RDS332864 var_EntityType dm:ClassOfInformationObject var_Definition UR PURCHASE ORDER map(SH1-Q28:AE28) for PUMP map(SH1-Q20:AE20) var_EffectiveDate map    
 
SERVICE   [ Continuous | Intermittent ] Pumping activity class (to be specialized with a Status CONTINUOUS or INTERMITTENT, as selected) SH2-AH11:AL11 PUMPING Activity Class

C

 

A

  N041 var_Type tip:DeclarationOfClassOfPhysicalObject var_Label map[{CO_}{map(SH1-Q20:AE20}{-ACT}] var_EssentialType rdl:RDS9657917 var_EntityType dm:ClassOfInanimatePhysicalObject var_Definition PUMPING ACTIVITY CLASS map[{CO_}{map(SH1-Q20:AE20}{-ACT}] for PUMP map(SH1-Q20:AE20) var_EffectiveDate map    
 
Suction Nozzle INLET NOZZLE (to be specialized) --- Suction Nozzle

C

 

A

  N050 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-IN}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS415214 var_Definition SUCTION NOZZLE of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20}] var_EffectiveDate map
Discharge Nozzle OUTLET NOZZLE (to be specialized) --- Discharge Nozzle

C

 

A

  N051 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-OUT}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS415214 var_Definition DISCHARGE NOZZLE of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20}}] var_EffectiveDate map
Aux connection - balance/leak-off A LEAKOFF PORT (to be specialized) --- Leakoff Connection

C

 

A

  N052 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-LOF}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS2226443 var_Definition LEAKOFF CONNECTION of PUMP REQUIREMENTS CLASS (IdentOfNode40). var_EffectiveDate map
Aux connection - drain A DRAIN PORT (to be specialized) --- Drain Connection

C

 

A

  N053 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-DRN}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS1330900681 var_Definition DRAIN CONNECTION of PUMP REQUIREMENTS CLASS (IdentOfNode40). var_EffectiveDate map
Aux connection - vent A VENTILATION PORT (to be specialized) --- Vent Connection

C

 

A

  N054 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-VNT}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS2195738221 var_Definition VENT CONNECTION of PUMP REQUIREMENTS CLASS (IdentOfNode40). var_EffectiveDate map
Aux. Connection - Pressure Gauge A PORT for a pressure gauge (to be specialized) --- Presure Gauge Connection

C

 

A

  N055 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-PGC}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS2195895131 var_Definition PRESSURE GAUGE CONNECTION of PUMP REQUIREMENTS CLASS (IdentOfNode40). var_EffectiveDate map
Aux. Connection - Temperature Gauge A PORT for a temperature gauge (to be specialized) --- Temperature Gauge Connection

C

 

A

  N056 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-TGC}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS2226441 var_Definition TEMPERATURE GAUGE CONNECTION of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Aux. Connection - warm-up line A PORT for a warm-up line (to be specialized) --- Warming-up Connection

C

 

A

  N057 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-WRM}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS2226444 var_Definition WARMING-UP LINE CONNECTION of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Cooling Water - inlet CW INLET NOZZLE (to be specialized) --- CW Inlet

C

 

A

  N058 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-CW-IN}] var_PartEntityType var_PartEntityType var_PartEssentialType rdl:RDS415214 var_Definition COOLING WATER INLET CONNECTION of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Cooling Water - outlet CW OUTLET NOZZLE (to be specialized) --- CW Outlet

C

 

A

  N059 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-CW-OUT}] var_PartEntityType var_PartEntityType var_PartEssentialType rdl:RDS415214 var_Definition COOLING WATER OUTLET CONNECTION of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
 
Accelerometer See RDL --- Accelerometer

C

 

A

  N060 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-ACC}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS222500 var_Definition ACCELEROMETER of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Baseplate See RDL --- Baseplate

C

 

A

  N061 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-BPL}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS2226415 var_Definition BASEPLATE of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Bearing See RDL --- Bearing

C

 

A

  N062 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-BRG}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS286874 var_Definition BEARING(S) of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Bowl See RDL --- Bowl

C

 

A

  N063 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-BWL}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS869669 var_Definition BOWL of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Casing See RDL --- Casing

C

 

A

  N064 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-CAS}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS13029297 var_Definition CASING of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Column Pipe See RDL --- Column Pipe

C

 

A

  N065 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-COL}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS879569 var_Definition COLUMN PIPE of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Cooling System See RDL --- Cooling System

C

 

A

  N066 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-COO}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS277244 var_Definition COOLING SYSTEM of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Coupling See RDL --- Coupling

C

 

A

  N067 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-CPG}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS431639 var_Definition COUPLING of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Discharge Head See RDL --- Discharge Head

C

 

A

  N068 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-DCH}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS2226600 var_Definition DISCHARGE HEAD of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Driver See RDL --- Driver

C

 

A

  N069 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-DRV}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS299024 var_Definition DRIVER of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Guide Bushing See RDL --- Guide Bushing

C

 

A

  N070 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-GBG}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS880244 var_Definition GUIDE BUSHING of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Heating System See RDL --- Heating System

C

 

A

  N071 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-HEA}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS276299 var_Definition HEATING SYSTEM of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Impeller(s) See RDL --- Impeller

C

 

A

  N072 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-IMP}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS414539 var_Definition IMPELLER(S) of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Line shaft See RDL --- Line shaft

C

 

A

  N073 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-SHF}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS879974 var_Definition LINE SHAFT of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Lubrication System See RDL --- Lubrication System

C

 

A

  N074 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-LUB}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS327419 var_Definition LUBRICATION SYSTEM of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Manifold Piping for Purchaser Connection See RDL --- Manifold Piping for Purchaser Connection

C

 

A

  N075 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-MAN}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS903171211 var_Definition MANIFOLD PIPING of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Mechanical Seal See RDL --- Mechanical Seal

C

 

A

  N076 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-MSL}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS446309 var_Definition MECHANICAL SEAL of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Rotor See RDL --- Rotor

C

 

A

  N077 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-ROT}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS415799 var_Definition ROTOR of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Seal Support System See RDL --- Seal Support System

C

 

A

  N078 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-SSS}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS14205079 var_Definition SEAL SUPPORT SYSTEM of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Soleplate See RDL --- Soleplate

C

 

A

  N079 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-SPL}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS329354 var_Definition SOLEPLATE of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Suction Can See RDL --- Suction Can

C

 

A

  N080 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-SCN}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS6695000 var_Definition SUCTION CAN of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Stage(s) See RDL --- Stage(s)

C

 

A

  N081 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-STG}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS14207419 var_Definition STAGE(S) of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Sump See RDL --- Sump

C

 

A

  N082 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-SMP}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS2226416 var_Definition SUMP of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Temperature Probe See RDL --- Temperature Probe

C

 

A

  N083 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-TPB}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS445454 var_Definition TEMPERATURE PROBE of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map
Vibration Probes See RDL --- Vibration Probes

C

 

A

  N084 var_Type tip:DeclarationOfComponentOfClassOfPhysicalObject var_LabelOfClassOfWhole map[{CO_}{map(SH1-Q20:AE20}] var_LabelOfClassOfPart map[{CO_}{map(SH1-Q20:AE20}{-VPB}] var_PartEntityType dm:ClassOfInanimatePhysicalObject var_PartEssentialType rdl:RDS435959 var_Definition VIBRATION PROBE of PUMP REQUIREMENTS CLASS map[{CO_}{map(SH1-Q20:AE20} var_EffectiveDate map

 

Step 2

Then we define all interrelationships between above declared objects. This is information that is implied but not made specific in the data sheet.

  

CENTRIFUGAL PUMP API 610, 11th Ed. DATA SHEET PROMPT (approx.)

NARRATIVE

VALUE CELL

 

AUDER

 

ID

TIP TYPE

VAR #1

VAR #2

VAR #3

VAR #4

VAR #5

  Class of Suction Nozzle is a part of the pump class    

A

  T9001 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N050 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222625 var_EffectiveDate map
  Class of Discharge Nozzle is a part of the pump class    

A

  T9002 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N051 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222625 var_EffectiveDate map
  Class of Leakoff Connection is a part of the pump class    

A

  T9003 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N052 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Drain Connection is a part of the pump class    

A

  T9004 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N053 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Vent Connection is a part of the pump class    

A

  T9005 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N054 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Presure Gauge Connection is a part of the pump class    

A

  T9006 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N055 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Temperature Gauge Connection is a part of the pump class    

A

  T9007 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N056 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Warming-up Connection is a part of the pump class    

A

  T9008 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N057 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Accelerometer is a part of the pump class    

A

  T9009 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N060 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Baseplate is a part of the pump class    

A

  T9010 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N061 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Bearing is a part of the pump class    

A

  T9011 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N062 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Bowl is a part of the pump class    

A

  T9012 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N063 var_CardinalityOfWhole rdl:RDS222625 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Casing is a part of the pump class    

A

  T9013 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N064 var_CardinalityOfWhole rdl:RDS222625 var_CardinalityOfPart rdl:RDS222625 var_EffectiveDate map
  Class of Column Pipe is a part of the pump class    

A

  T9014 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N065 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Cooling System is a part of the pump class    

A

  T9015 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N066 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Coupling is a part of the pump class    

A

  T9016 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N067 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Discharge Head is a part of the pump class    

A

  T9017 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N068 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Driver is a part of the pump class    

A

  T9018 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N069 var_CardinalityOfWhole rdl:RDS222625 var_CardinalityOfPart rdl:RDS222625 var_EffectiveDate map
  Class of Guide Bushing is a part of the pump class    

A

  T9019 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N070 var_CardinalityOfWhole rdl:RDS222625 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Heating System is a part of the pump class    

A

  T9020 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N071 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Impeller is a part of the pump class    

A

  T9021 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N072 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222625 var_EffectiveDate map
  Class of Line shaft is a part of the pump class    

A

  T9022 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N073 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222625 var_EffectiveDate map
  Class of Lubrication System is a part of the pump class    

A

  T9023 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N074 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Manifold Piping for Purchaser Connection is a part of the pump class    

A

  T9024 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N075 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Mechanical Seal is a part of the pump class    

A

  T9025 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N076 var_CardinalityOfWhole rdl:RDS222625 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Rotor is a part of the pump class    

A

  T9026 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N077 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222625 var_EffectiveDate map
  Class of Seal Support System is a part of the pump class    

A

  T9027 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N078 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Soleplate is a part of the pump class    

A

  T9028 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N079 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Suction Can is a part of the pump class    

A

  T9029 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N080 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Stage(s) is a part of the pump class    

A

  T9030 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N081 var_CardinalityOfWhole rdl:RDS999900701 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Sump is a part of the pump class    

A

  T9031 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N082 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Temperature Probe is a part of the pump class    

A

  T9032 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N083 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  Class of Vibration Probes is a part of the pump class    

A

  T9033 var_Type tip:ClassOfAssemblyDefinition var_ClassOfWhole N040 var_ClassOfPart N084 var_CardinalityOfWhole rdl:RDS222624 var_CardinalityOfPart rdl:RDS222624 var_EffectiveDate map
  The Pump is listed on the REQUISITION    

A

  T2001 var_Type tip:ReferenceToIndividualOnDocument var_Referred N010 var_Document N032 var_EffectiveDate map        
  The Pump is listed on the SPECIFICATION.    

A

  T2001 var_Type tip:ReferenceToIndividualOnDocument var_Referred N010 var_Document N030 var_EffectiveDate map        
  The Pump is listed on the PURCHASE ORDER.    

A

  T2001 var_Type tip:ReferenceToIndividualOnDocument var_Referred N010 var_Document N033 var_EffectiveDate map        
  The Pump  is  classified with the Pump Requirement Class    

A

  T2003 var_Type tip:ClassoificationOfIndividual var_Classified N010 var_Classifier N040 var_EffectiveDate map        
UNIT The Pump is a part of the assembly of a Process Unit    

A

  T2004 var_Type tip:ClassOfAssemblyDefinition var_Whole N014 var_Part N010 var_EffectiveDate map        
SITE The pump is a part of the arrangement of the plant site     

A

  T2005 var_Type tip:ArrangementOfAnIndividual var_Whole N015 var_Part N010 var_EffectiveDate map        
LOCATION The pump is located inside a particular part of the plant.    

A

  T2301 var_Type tip:ContainmentOfAnIndividual var_Container N013 var_Contained N010 var_EffectiveDate map        
ELECTRICITY FOR DRIVERS (location) The power distributor for ELECTRICITY FOR DRIVERS  is located inside the applicable Pump Location.    

A

  T2302 var_Type tip:RelativeLocationOfIndividual var_Located N019 var_Locator N013 var_RelativeLocationType rdl:RDS2229920 var_EffectiveDate map    
ELECTRICITY FOR HEATING (location) The power distributor for ELECTRICITY FOR HEATING  is located inside the applicable Pump Location.    

A

 

T2303

var_Type tip:RelativeLocationOfIndividual var_Located N020 var_Locator N013 var_RelativeLocationType rdl:RDS2229920 var_EffectiveDate map    
ELECTRICITY FOR CONTROL (location) The power distributor for ELECTRICITY FOR CONTROL  is located inside the applicable Pump Location.    

A

 

T2304

var_Type tip:RelativeLocationOfIndividual var_Located N021 var_Locator N013 var_RelativeLocationType rdl:RDS2229920 var_EffectiveDate map    
ELECTRICITY FOR SHUTDOWN (location) The power distributor for ELECTRICITY FOR SHUTDOWN  is located inside the applicable Pump Location.    

A

 

T2305

var_Type tip:RelativeLocationOfIndividual var_Located N022 var_Locator N013 var_RelativeLocationType rdl:RDS2229920 var_EffectiveDate map    

 

Step 3A

Now we start with mapping the data found on page 1

   

CENTRIFUGAL PUMP API 610, 11th Ed. DATA SHEET PROMPT (approx.)

NARRATIVE

VALUE CELL

 

AUDER

 

ID

TIP TYPE

VAR #1

VAR #2

VAR #3

VAR #4

VAR #5

CLIENT The CLIENT participates in the PROJECT activity in the Role of CONTRACT OWNER. SH1-Q14:AE14  

A

  T2001 var_Type tip:ParticipationInActivity var_Activity N001 var_Participant N002 var_ParticipantClass rdl:RDS2229882 var_ParticipantRole rdl:RDS2229017 var_EffectiveDate map
PROJECT TITLE The PROJECT is described with a PROJECT TITLE. SH1-Q16:AE16  

A

  T2001 var_Type tip:ClassifiedDescriptionOfIndividual var_Described N001 var_Descriptor map(SH2-Q16:AE16) var_DescriptionType rdl:RDS2229780 var_EffectiveDate map    
JOB NUMBER JOB = PROJECT, and this number is the rdsf:label of the declared PROJECT, Node N001 SH1-Q18:AE18                                
EQUIPMENT NUMBER The EQUIPMENT NUMBER is assumed to be the TAG NUMBER, and that has already been taken care of in the declaration of Node N010 SH1-Q20:AE20                                
EQUIPMENT SERVICE The EQUIPMENT SERVICE has already been taken care of for SH2-Y6:AL6 SH1-Q22:AE22                                
SERIAL NUMBER The SERIAL NUMBER has already been taken care of for SH2-AH8:AL8 SH1-Q24:AE24                                
REQ . NO. The Pump is listed on the REQUISITION; is listed under Interrelations. SH1-Q26:W26                                
SPEC NO. The Pump is listed on the SPECIFICATION; is listed under Interrelations. SH1-Y26:AE26                                
PURCH ORDER NO. The Pump is listed on the PURCHASE ORDER; is listed under Interrelations. SH1-Q28:AE28                                

 

Step 3B

This is followed by the mapping of the data on page 2. Note that this is partly complete.

In this phase the pick-lists are being introduced to present a valid choice for a variable. For example in the first line below, variable #1 has such a pick-list, because the data sheet gives a choice between PROPOSING | PURCHASING | DESCRIBING AS-BUILT SITUATION: oneOfN9001 refers to the following pick-list:

ID

TIP TYPE

VAR #1

VAR #2

VAR #3

N9001 var_Type tip:DeclarationOfEnumeratedSetOfClass var_EntityType dm:EnumeratedSetOfClass var_Label "API 610 APPLICABLE TO Proposal | Purchase | As Built" var_EffectiveDate map
T9001 var_Type tip:EnumerationOfClass

var_Set

N9001

var_Member

rdl:RDS2226610

var_EffectiveDate

map

T9002 var_Type tip:EnumerationOfClass

var_Set

N9001

var_Member

rdl:RDS9657962 

var_EffectiveDate

map

T9003 var_Type tip:EnumerationOfClass

var_Set

N9001

var_Member

rdl:RDS2226611

var_EffectiveDate

map

 

The three members of the EnumeratedSetOfClass are the choices.

Click here for the pick-lists used below.

  

  

CENTRIFUGAL PUMP API 610, 11th Ed. DATA SHEET PROMPT (approx.)

NARRATIVE

VALUE CELL

 

AUDER

 

ID

TIP TYPE

VAR #1

VAR #2

VAR #3

VAR #4

VAR #5

VAR #6

VAR #7

VAR #8

APPLICABLE TO  Proposal | Purchase | As Built This Document-Revision is involved by reference in an Activity classified either as PROPOSING | PURCHASING | DESCRIBING AS-BUILT SITUATION. SH2-H4:L4  

A

  T2001 var_Type tip:ClassOfInvolvementByReferenceDefinition var_ActivityType oneOfN9001 var_InvolvedType N031 var_InvolvementRole rdl:RDS2229889 var_CardinalityOfInvolved rdl:RDS222625 var_CardinalityOfActivity rdl:RDS222625 var_EffectiveDate map var_LifecycleActivity oneOfN9001    
APPLICABLE NTL/INTNTL STANDARD The Pump Requirement Class is defined by this Document, and that definition is in accordance with one of:  API 610 | ASME B73.1 | ASME B73.2 | PIP RESP73H-97 | PIP RESP73V-P7 | ISO | OTHER (the latter has not been mapped). SH2-Y4:AC4  

A

  T2002 var_Type tip:ClassificationOfClassOfIndividual var_Classified N040 var_Classifier oneOfN9002 var_EffectiveDate map var_LifecycleActivity rdl:RDS9704537                
SERVICE The Pump has a service description. SH2-X6:AL6  

A

  T2005 var_Type tip:ClassifiedDescriptionOfIndividual var_Described N010 var_Descriptor map{SH2-X6:AL6) var_DescriptionType rdl:RDS2229180 var_EffectiveDate map var_LifecycleActivity rdl:RDS9704537            
NO. REQ. The quantity of identical pumps as defined in this data sheet. SH2-F7:H7  

A

  T2006 var_Type tip:AggregateOfMonotypeIndividual var_Aggregate anyId var_CollectorType rdl:RDS2226606 var_ObjectType rdl:RDS416834 var_AggregateCount map(SH2-F7:H7) var_EffectiveDate map var_LifecycleActivity rdl:RDS9704537        
PUMP SIZE The size of the offered, purchased, or as-built (depending on "APPLICABLE TO  [ Proposal | Purchase | As Built ]") actual Pump. SH2-M7:T7  

A

  T2007 var_Type tip:IndividualHasIndirectPropertyWithValue var_Possessor oneOf(N004, N010) var_IndirectPropertyType rdl:RDS2229888 var_PropertyValue map(SH2-M7:T7) var_Scale oneOfN9003 var_EffectiveDate map var_LifecycleActivity oneOfN9001        
TYPE The type of the offered, purchased, or as-built (depending on "APPLICABLE TO  [ Proposal | Purchase | As Built ]") actual Pump according the standard referred to at "APPLICABLE NTL/INTNTL STANDARD". SH2-Y7:AB7  

A

  T2008 var_Type tip:ClassificationOfIndividual var_Classified N004 var_Classifier map(SH2-Y7:AB7) var_EffectiveDate map var_LifecycleActivity oneOfN9001                
No. STAGES The number of stages of the offered, purchased, or as-built (depending on "APPLICABLE TO  [ Proposal | Purchase | As Built ]") actual Pump. SH2-AH7:AL7  

A

  T2009 var_Type tip:ClassificationOfIndividual var_Classified N004 var_Classifier oneOfN9004 var_EffectiveDate map var_LifecycleActivity oneOfN9001                
MANUFACTURER The manufacturer of the offered or purchased (depending on "APPLICABLE TO  [ Proposal | Purchase | As Built ]") actual Pump. SH2-H8:T8  

A

  T2010 var_Type tip:ProductManufacturedBy var_Product N004 var_Manufacturer map(SH2-H8:T8) var_ManufactureType rdl:RDS2229929 var_EffectiveDate map var_LifecycleActivity oneOfN9001            
MODEL The model number of the offered, purchased, or as-built (depending on "APPLICABLE TO  [ Proposal | Purchase | As Built ]") actual Pump. SH2-Y8:AB8  

A

  T2011 var_Type tip:ClassificationOfIndividual var_Classified N004 var_Classifier map(SH2-Y8:AB8) var_EffectiveDate map var_LifecycleActivity oneOfN9001                
SERIAL NO. The serial number of the supplied actual Pump. SH2-AH8:AL8  

A

  T2012 var_Type tip:ClassifiedIdentificationOfIndividual var_Identified N004 var_Label map{SH2-AH8:AL8) var_IdentificationType rdl:RDS2221101 var_EffectiveDate map var_LifecycleActivity rdl:RDS9653102            
LIQUID CHARACTERISTICS      

 

                                       
LIQUID TYPE OR NAME Stream is classified with the (required) Stream Class SH2-K12:S12  

A

  T2101 var_Type tip:ClassificationOfIndividual var_Classified N016 var_Classifier N042 var_EffectiveDate map var_LifecycleActivity                  
--- StreamIn is a part of Stream ---  

A

  T2102 var_Type tip:CompositionOfAnIndividual var_Whole N016 var_Part N017 var_EffectiveDate map var_LifecycleActivity                  
--- StreamOut is a Part of Stream ---  

A

  T2104 var_Type tip:CompositionOfAnIndividual var_Whole N016 var_Part N018 var_EffectiveDate map var_LifecycleActivity                  
MAXIMUM VAPOR PRESSURE  kPa(a) |  psia  IndirectProperty possessed by the Stream class SH2-N13:P13  

A

  T2111 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMaximumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229890 var_MaximumValue map(SH2-N13:P13) var_Scale oneOfN9005 var_EffectiveDate map var_LifecycleActivity          
MINIMUM VAPOR PRESSURE  kPa(a) | psia  IndirectProperty possessed by the Stream class SH2-Q13:S13  

A

  T2112 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMinimumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229891 var_MinimumValue map(SH2-Q13:S13) var_Scale oneOfN9005 var_EffectiveDate map var_LifecycleActivity          
MAXIMUM RELATIVE DENSITY IndirectProperty possessed by the Stream class SH2-N14:P14  

A

  T2113 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMaximumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229892 var_MaximumValue map(SH2-N14:P14) var_Scale rdl:RDS2223607 var_EffectiveDate map var_LifecycleActivity          
MINIMUM RELATIVE DENSITY IndirectProperty possessed by the Stream class SH2-Q14:S14  

A

  T2114 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMinimumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229893 var_MinimumValue map(SH2-Q14:S14) var_Scale rdl:RDS2223607 var_EffectiveDate map var_LifecycleActivity          
MAXIMUM SPECIFIC HEAT kJ/kgC | BTU/lbm F IndirectProperty possessed by the Stream class SH2-N15:P15  

A

  T2115 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMaximumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229894 var_MaximumValue map(SH2-N15:P15) var_Scale oneOfN9007 var_EffectiveDate map var_LifecycleActivity          
MINIMUM SPECIFIC HEAT   kJ/kgC | BTU/lbm F IndirectProperty possessed by the Stream class SH2-Q15:S15  

A

  T2116 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMinimumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229895 var_MinimumValue map(SH2-Q15:S15) var_Scale oneOfN9007 var_EffectiveDate map var_LifecycleActivity          
MAXIMUM VISCOSITY  Pa s | cP  IndirectProperty possessed by the Stream class SH2-N16:P16  

A

  T2117 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMaximumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229896 var_MaximumValue map(SH2-N16:P16) var_Scale oneOfN9008 var_EffectiveDate map var_LifecycleActivity          
MINIMUM VISCOSITY  Pa s | cP IndirectProperty possessed by the Stream class SH2-Q16:S16  

A

  T2118 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMinimumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229897 var_MinimumValue map(SH2-Q16:S16) var_Scale oneOfN9008 var_EffectiveDate map var_LifecycleActivity          
OPERATING CONDITIONS      

 

                                       
NPSHA Datum  Centerline Impeller | Top of foundation | Suction nozzle The template with T2144 is described with a note SH2-N20:Y20  

A

  T2119 var_Type tip:ClassifiedDescriptionOfTemplate var_TemplateId :<T2144> var_Descriptor "NPSHA Datum is [ Centerline Impeller | Top of foundation | Suction nozzle ]" var_DescriptionType rdl:RDS2229018 var_EffectiveDate map var_LifecycleActivity              
MAXIMUM PUMPING TEMPERATURE K | C | F IndirectProperty possessed by the Stream class SH2-N21:P21  

A

  T2120 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMaximumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS400184 var_MaximumValue map(SH2-N21:P21) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity          
RATED PUMPING TEMPERATURE K | C | F IndirectProperty possessed by the Stream class SH2-Q21:S21  

A

  T2121 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229899 var_PropertyValue map(SH2-Q21:S21) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity          
NORMAL PUMPING TEMPERATURE  K | C | F IndirectProperty possessed by the Stream class SH2-T21:V21  

A

  T2122 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS369674 var_PropertyValue map(SH2-T21:V21) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity          
MINIMUM PUMPING TEMPERATURE  K | C | F IndirectProperty possessed by the Stream class SH2-W21:Y21  

A

  T2123 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMinimumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS400229 var_MinimumValue map(SH2-W21:Y21) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity          
MAXIMUM FLOW  m/h | gpm IndirectProperty possessed by the Stream class SH2-N22:P22  

A

  T2124 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMaximumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS7353960 var_MaximumValue map(SH2-N22:P22) var_Scale oneOfN9010 var_EffectiveDate map var_LifecycleActivity          
RATED FLOW  m/h | gpm IndirectProperty possessed by the Stream class SH2-Q22:S22  

A

  T2125 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS4720595 var_PropertyValue map(SH2-Q22:S22) var_Scale oneOfN9010 var_EffectiveDate map var_LifecycleActivity          
NORMAL FLOW  m/h | gpm IndirectProperty possessed by the Stream class SH2-T22:V22  

A

  T2126 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS7354451 var_PropertyValue map(SH2-T22:V22) var_Scale oneOfN9010 var_EffectiveDate map var_LifecycleActivity          
MINIMUM FLOW  m/h | gpm IndirectProperty possessed by the Stream class SH2-W22:Y22  

A

  T2127 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMinimumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS400679 var_MinimumValue map(SH2-W22:Y22) var_Scale oneOfN9010 var_EffectiveDate map var_LifecycleActivity          
MAXIMUM DISCHARGE PRESSURE  kPa(g) | psig Stream class has a MAXIMUM PRESSURE at location Discharge Nozzle of Pump SH2-N23:P23  

A

  T2128 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMaximumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS14151900 var_MaximumValue map(SH2-N23:P23) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
RATED DISCHARGE PRESSURE kPa(g) | psig Stream class has a RATED PRESSURE at location Discharge Nozzle of Pump SH2-Q23:S23  

A

  T2129 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS14151838 var_PropertyValue map(SH2-Q23:S23) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
NORMAL DISCHARGE PRESSURE kPa(g) | psig Stream class has a NORMAL PRESSURE at location Discharge Nozzle of Pump SH2-T23:V23  

A

  T2130 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2229898 var_PropertyValue map(SH2-T23:V23) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
MINIMUM DISCHARGE PRESSURE  kPa(g) | psig Stream class has a MINIMUM PRESSURE at location Discharge Nozzle of Pump SH2-W23:Y23  

A

  T2131 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMinimumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS14151962 var_MinimumValue map(SH2-W23:Y23) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
MAXIMUM SUCTION PRESSURE  kPa(g) | psig Stream class has a MAXIMUM PRESSURE at location Inlet Nozzle of Pump SH2-N24:P24  

A

  T2132 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMaximumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS400724 var_MaximumValue map(SH2-N24:P24) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
RATED SUCTION PRESSURE  kPa(g) | psig Stream class has a RATED PRESSURE at location Inlet Nozzle of Pump SH2-Q24:S24  

A

  T2133 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS2223470 var_PropertyValue map(SH2-Q24:S24) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
NORMAL SUCTION PRESSURE  kPa(g) | psig Stream class has a NORMAL PRESSURE at location Inlet Nozzle of Pump SH2-T24:V24  

A

  T2134 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS7343782 var_PropertyValue map(SH2-T24:V24) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
MINIMUM SUCTION PRESSURE  kPa(g) | psig Stream class has a MINIMUM PRESSURE at location Inlet Nozzle of Pump SH2-W24:Y24  

A

  T2135 var_Type tip:ClassOfIndividualHasIndirectPropertyWithMinimumValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS400769 var_MinimumValue map(SH2-W24:Y24) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
MAXIMUM DIFFERENTIAL PRESSURE  kPa | psi Maximum difference in values of Pressure at Discharge and at Suction of Pump SH2-N25:P25  

A

  T2136 var_Type tip:MaximumDifferentialPropertyBetweenClassesOfIndividual var_HighPossessorType N018 var_LowPossessorType N017 var_IndirectPropertyType map(SH2-N25:P25) var_MaximumValue SH2-N25:P25 var_Scale oneOfN9006 var_EffectiveDate map var_LifecycleActivity      
RATED DIFFERENTIAL PRESSURE  kPa | psi Rated difference in values of Pressure at Discharge and at Suction of Pump SH2-Q25:S25  

A

  T2137 var_Type tip:DifferentialPropertyBetweenClassesOfIndividual var_HighPossessorType N018 var_LowPossessorType N017 var_IndirectPropertyType map(SH2-Q25:S25) var_PropertyValue SH2-Q25:S25 var_Scale oneOfN9006 var_EffectiveDate map var_LifecycleActivity      
NORMAL DIFFERENTIAL PRESSURE  kPa | psi Normal difference in values of Pressure at Discharge and at Suction of Pump SH2-T25:V25  

A

  T2138 var_Type tip:DifferentialPropertyBetweenClassesOfIndividual var_HighPossessorType N018 var_LowPossessorType N017 var_IndirectPropertyType map(SH2-T25:V25) var_PropertyValue SH2-T25:V25 var_Scale oneOfN9006 var_EffectiveDate map var_LifecycleActivity      
MINIMUM DIFFERENTIAL PRESSURE  kPa | psi Minimum difference in values of Pressure at Discharge and at Suction of Pump SH2-W25:Y25  

A

  T2139 var_Type tip:MinimumDifferentialPropertyBetweenClassesOfIndividual var_HighPossessorType N018 var_LowPossessorType N017 var_IndirectPropertyType map(SH2-W25:Y25) var_MinimumValue SH2-W25:Y25 var_Scale oneOfN9006 var_EffectiveDate map var_LifecycleActivity      
MAXIMUM DIFFERENTIAL HEAD   m | ft Maximum difference in values of Head at Discharge of Pump and NPSHA SH2-N26:P26  

A

  T2140 var_Type tip:MaximumDifferentialPropertyBetweenClassesOfIndividual var_HighPossessorType N018 var_LowPossessorType N017 var_IndirectPropertyType map(SH2-N26:P26) var_MaximumValue SH2-N26:P26 var_Scale oneOfN9006 var_EffectiveDate map var_LifecycleActivity      
RATED DIFFERENTIAL HEAD   m | ft Rated difference in values of Head at Discharge of Pump and NPSHA SH2-Q26:S26  

A

  T2141 var_Type tip:DifferentialPropertyBetweenClassesOfIndividual var_HighPossessorType N018 var_LowPossessorType N017 var_IndirectPropertyType map(SH2-Q26:S26) var_PropertyValue SH2-Q26:S26 var_Scale oneOfN9006 var_EffectiveDate map var_LifecycleActivity      
NORMAL DIFFERENTIAL HEAD   m | ft Normal difference in values of Head at Discharge of Pump and NPSHA SH2-T26:V26  

A

  T2142 var_Type tip:DifferentialPropertyBetweenClassesOfIndividual var_HighPossessorType N018 var_LowPossessorType N017 var_IndirectPropertyType map(SH2-T26:V26) var_PropertyValue SH2-T26:V26 var_Scale oneOfN9006 var_EffectiveDate map var_LifecycleActivity      
MINIMUM DIFFERENTIAL HEAD   m | ft Minimum difference in values of Head at Discharge of Pump and NPSHA SH2-W26:Y26  

A

  T2143 var_Type tip:MinimumDifferentialPropertyBetweenClassesOfIndividual var_HighPossessorType N018 var_LowPossessorType N017 var_IndirectPropertyType map(SH2-W26:Y26) var_MinimumValue SH2-W26:Y26 var_Scale oneOfN9006 var_EffectiveDate map var_LifecycleActivity      
RATED NPSHA   m | ft Stream class exerts a Pressure at the above NPSHA Datum that is expressed in the length of a column of that liquid. SH2-Q27:S27  

A

  T2144 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS14331074 var_PropertyValue map(SH2-Q27:S27) var_Scale oneOfN9012 var_EffectiveDate map var_LifecycleActivity          
RATED HYDRAULIC POWER  kW | HP IndirectProperty possessed by the Pump class SH2-Q28:S28  

A

  T2145 var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N016 var_IndirectPropertyType rdl:RDS4720595 var_PropertyValue map(SH2-Q28:S28) var_Scale oneOfN9013 var_EffectiveDate map            
SERVICE CONDITIONS      

 

                                       
SERVICE   Continuous | Intermittent  The Pump will run continuously or intermittently.    

A

  T2201 var_Type tip:SpecializationOfClassOfIndividual var_SubClass N041 var_SuperClass oneOfN9014 var_EffectiveDate map var_LifecycleActivity                  
NUMBER OF STARTS / DAY In case the Pump will run intermittently the expected number of starts/day of the Drive is    

A

  T2202 var_Type tip:ClassifiedDefinitionOfClassOfIndividual var_Defined N069 var_Definition map(AK12:AL12) starts per day. var_DefinitionType rdl:RDS2220049 var_EffectiveDate map var_LifecycleActivity              
PUMPS OPERATE IN   Parallel | Series  The Pump will operate in parallel with another pump, or in series with another pump.    

A

  T2203 var_Type tip:ClassifiedDefinitionOfClassOfIndividual var_Defined N040 var_Definition pump runs in map(AK13:AL13). var_DefinitionType rdl:RDS2220049 var_EffectiveDate map var_LifecycleActivity              
CORROSION DUE TO  Corrosive agents (including trace quantities) present in the process liquids and in the site environment, including constituents that can cause stress-corrosion cracking or attack elastomers.    

A

  T2204 var_Type tip:ClassOfCompositionDefinitionWithStatus var_ClassOfWhole N016 var_LabelOfClassOfPart map(AK14:AL14) var_EffectiveDate map var_LifecycleActivity                  
EROSION DUE TO  Erosive agents (including trace quantities) present in the process liquids and in the site environment, including constituents that can attack elastomers.    

A

  T2205 var_Type tip:ClassOfCompositionDefinitionWithStatus var_ClassOfWhole N016 var_LabelOfClassOfPart map(AK15:AL15) var_EffectiveDate map var_LifecycleActivity                  
H2S CONCENTRATION    ppm  If chlorides are present in the pumped liquid in a concentration above 10 mg/kg (10 ppm), it is necessary to use
caution when applying stainless steel.
   

A

  T2206 var_Type tip:ClassOfCompositionDefinitionWithRatio var_ClassOfWhole N016 var_ClassOfPart rdl:RDS2223482 var_Ratio map(AK16:AL16) var_Scale rdl:RDS1333484 var_EffectiveDate map var_LifecycleActivity          
CHLORIDE CONCENTRATION    ppm Stream class has a Chloride concentration in ppm    

A

  T2207 var_Type tip:ClassOfCompositionDefinitionWithRatio var_ClassOfWhole N016 var_ClassOfPart rdl:RDS2223483 var_Ratio map(AK18:AL18) var_Scale rdl:RDS1333484 var_EffectiveDate map var_LifecycleActivity          
PARTICULATE SIZE (DIAMETER)     micron  Stream has entrained particles that have a given diameter in microns    

A

  T2208 var_Type tip:ClassOfComponentSize var_ClassOfWhole N016 var_ClassOfPart lci:ParticulateObject var_Diameter map(AK19:AL19) var_Scale rdl:RDS1351529 var_EffectiveDate map var_LifecycleActivity          
PARTICULATE CONCENTRATION    ppm  Stream has entrained particles concentration in ppm    

A

  T2209 var_Type tip:ClassOfCompositionDefinitionWithRatio var_ClassOfWhole N016 var_ClassOfPart lci:ParticulateObject var_Ratio map(AK20:AL20) var_Scale rdl:RDS1333484 var_EffectiveDate map var_LifecycleActivity          
PARTICULATE CONCENTRATION    ppm  Stream has entrained particles concentration in ppm    

A

  T2209 var_Type tip:ClassOfCompositionDefinitionWithRatio var_ClassOfWhole N016 var_ClassOfPart lci:ParticulateObject var_Ratio map(AK20:AL20) var_Scale rdl:RDS1333484 var_EffectiveDate map var_LifecycleActivity          
SITE DATA      

 

                                       
LOCATION - Indoor | Outdoor The pump is located inside the SpatialLocation and the latter is classified as either INDOOR LOCATION or OUTDOOR LOCATION.    

A

  T2302 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9015 var_EffectiveDate map var_LifecycleActivity                  
LOCATION - Heated | Unheated The pump is located inside the SpatialLocation and the latter is classified as either HEATED LOCATION or UNHEATED LOCATION.    

A

  T2303 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9016 var_EffectiveDate map var_LifecycleActivity                  
LOCATION - Under roof | Partial sides The pump is located inside the SpatialLocation and the latter is classified as either UNDER-ROOF LOCATION or  LOCATION UNDER ROOF WITH PARTIAL SIDES.    

A

  T2304 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9017 var_EffectiveDate map var_LifecycleActivity                  
MOUNTED AT - Grade | Mezzanine The pump is mounted inside a SpatialLocation and the latter is classified as either GRADE LOCATION or MEZANINE LOCATION.    

A

  T2305 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9018 var_EffectiveDate map var_LifecycleActivity                  
Winterisation reqd | Tropicalisation reqd The pump is participating in an activity TROPICALIZING or WINTERIZING in the Role of SUBJECT (IFF anything is filled out).    

A

  T2306 var_Type tip:ClassOfParticipationApplicableYesNo var_ActivityType oneOfN9019 var_ParticipantType N040 var_ParticipantRole rdl:RDS222362 var_ApplicableYesNo oneOfN9020 var_CardinalityOfActivity rdl:RDS999900701 var_CardinalityOfParticipant rdl:RDS222625 var_EffectiveDate map var_LifecycleActivity  
 ELECTRIC AREA CLASSIFICATION - Class The location of the individual designed Pump is classified with Area Class (NEC standard - iff "customary units" have been selected).    

A

  T2307 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9021 var_EffectiveDate map var_LifecycleActivity                  
ELECTRIC AREA CLASSIFICATION - Group The location of the individual designed Pump is classified with the Group Class (NEC standard - iff "customary units" have been selected).    

A

  T2308 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9022 var_EffectiveDate map var_LifecycleActivity                  
ELECTRIC AREA CLASSIFICATION - Division The location of the individual designed Pump is classified with the  Division Class (NEC standard - iff "customary units" have been selected).    

A

  T2309 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9023 var_EffectiveDate map var_LifecycleActivity                  
ELECTRIC AREA CLASSIFICATION - Temp.Class The location of the individual designed Pump is classified with the Temperature Class (NEC standard - iff "customary units" have been selected).    

A

  T2310 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9024 var_EffectiveDate map var_LifecycleActivity                  
 ELECTRIC AREA CLASSIFICATION - Group The location of the individual designed Pump is classified with the Gas Group (IEC standard - iff SI Units have been selected).    

A

  T2311 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9025 var_EffectiveDate map var_LifecycleActivity                  
ELECTRIC AREA CLASSIFICATION - Zone The location of the individual designed Pump is classified with the Zone   (IEC standard - iff SI Units have been selected).    

A

  T2312 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9026 var_EffectiveDate map var_LifecycleActivity                  
ELECTRIC AREA CLASSIFICATION - Temp.Class The location of the individual designed Pump is classified with the Temperature class (IEC standard - iff SI Units have been selected).    

A

  T2313 var_Type tip:ClassificationOfIndividual var_Classified N013 var_Classifier oneOfN9027 var_EffectiveDate map var_LifecycleActivity                  
ELEVATION (MSL)    m | ft The elevation of the plant site with respect to Main Sea Level.    

A

  T2314 var_Type tip:IndividualHasPropertyWithValue var_Possessor N013 var_PropertyType rdl:RDS2223543 var_PropertyValue map(I37:J37) var_Scale oneOfN9012 var_EffectiveDate map var_LifecycleActivity          
BAROMETER   mmHg | inch Hg The average barometric pressure of the plant site.    

A

  T2315 var_Type tip:IndividualHasIndirectPropertyWithValue var_Possessor N013 var_IndirectPropertyType rdl:RDS2223544 var_PropertyValue map(Q37:R37) var_Scale rdl:RDS2229869 var_EffectiveDate map var_LifecycleActivity          
RANGE OF AMBIENT TEMPS - Minimum K | C | F The minimum ambient temperature at the plant site.    

A

  T2316 var_Type tip:IndividualHasIndirectPropertyWithMinimumValue var_Possessor N013 var_IndirectPropertyType rdl:RDS2223546 var_MinimumValue map(N38:O38) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity          
RANGE OF AMBIENT TEMPS - Maximum K | C | F The maximum ambient temperature at the plant site.    

A

  T2317 var_Type tip:IndividualHasIndirectPropertyWithMaximumValue var_Possessor N013 var_IndirectPropertyType rdl:RDS2223545 var_MaximumValue map(Q38:R38) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity          
RELATIVE HUMIDITY - Minimum The minimum relative humidity at the plant site.    

A

  T2318 var_Type tip:IndividualHasIndirectPropertyWithMinimumValue var_Possessor N013 var_IndirectPropertyType rdl:RDS2223548 var_MinimumValue map(N39:O39) var_Scale rdl:RDS1317959 var_EffectiveDate map var_LifecycleActivity          
RELATIVE HUMIDITY - Maximum The maximum relative humidity at the plant site.    

A

  T2319 var_Type tip:IndividualHasIndirectPropertyWithMaximumValue var_Possessor N013 var_IndirectPropertyType rdl:RDS2223547 var_MaximumValue map(Q39:R39) var_Scale rdl:RDS1317959 var_EffectiveDate map var_LifecycleActivity          
UNUSUAL CONDITIONS  Dust | Fumes | Dust & Fumes | Other Unusual conditions in the plant site under which the Pump will have to operate.    

A

  T2320 var_Type tip:IndividualHasStatus var_Possessor N013 var_Status oneOfN9028 var_EffectiveDate map var_LifecycleActivity                  
UTILITY DATA      

 

                                       
ELECTRICITY FOR DRIVERS - VOLTAGE   V  The Voltage of the electricity that is required to be available for the Pump Driver and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N019C var_IndirectPropertyType rdl:RDS2223530 var_PropertyValue map(H44:J44) var_Scale rdl:RDS1347974 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR DRIVERS - PHASE The Phase of the electricity that is required to be available for the Pump Driver and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N019C var_IndirectPropertyType rdl:RDS2224474 var_PropertyValue map(H45:J45) var_Scale rdl:RDS1059740901 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR DRIVERS - FREQUENCY   Hz  The Frequency of the electricity that is required to be available for the Pump Driver and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N019C var_IndirectPropertyType rdl:RDS2229535 var_PropertyValue map(H46:J46) var_Scale rdl:RDS1326464 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR HEATING - VOLTAGE     V  The Voltage of the electricity that is required to be available for any pump unit-related heating and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N020C var_IndirectPropertyType rdl:RDS2223530 var_PropertyValue map(K44:M44) var_Scale rdl:RDS1347974 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR HEATING - PHASE The Phase of the electricity that is required to be available for any pump unit-related heating and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N020C var_IndirectPropertyType rdl:RDS2224474 var_PropertyValue map(K45:M45) var_Scale rdl:RDS1059740901 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR HEATING - FREQUENCY  Hz  The Frequency of the electricity that is required to be available for any pump unit-related heating and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N020C var_IndirectPropertyType rdl:RDS2229535 var_PropertyValue map(K46:M46) var_Scale rdl:RDS1326464 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR CONTROL - VOLTAGE     V  The Voltage of the electricity that is required to be available for any pump-related controls and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N021C var_IndirectPropertyType rdl:RDS2223530 var_PropertyValue map(N44:P44) var_Scale rdl:RDS1347974 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR CONTROL - PHASE The Phase of the electricity that is required to be available for any pump-related controls and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N021C var_IndirectPropertyType rdl:RDS2224474 var_PropertyValue map(N45:P45) var_Scale rdl:RDS1059740901 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR CONTROL - FREQUENCY  Hz  The Frequency of the electricity that is required to be available for any pump-related controlsand to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N021C var_IndirectPropertyType rdl:RDS2229535 var_PropertyValue map(N46:P46) var_Scale rdl:RDS1326464 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR SHUTDOWN - VOLTAGE    V  The Voltage of the electricity that is required to be available for any pump-related shutdown system and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N022C var_IndirectPropertyType rdl:RDS2223530 var_PropertyValue map(Q44:S44) var_Scale rdl:RDS1347974 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR SHUTDOWN - PHASE The Phase of the electricity that is required to be available for any pump-related shutdown system and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N022C var_IndirectPropertyType rdl:RDS2224474 var_PropertyValue map(Q45:S45) var_Scale rdl:RDS1059740901 var_EffectiveDate map var_LifecycleActivity          
ELECTRICITY FOR SHUTDOWN - FREQUENCY  Hz  The Frequency of the electricity that is required to be available for any pump-related shutdown system and to be made available at battery limit.    

A

    var_Type tip:ClassOfIndividualHasIndirectPropertyWithValue var_PossessorType N022C var_IndirectPropertyType rdl:RDS2229535 var_PropertyValue map(Q46:S46) var_Scale rdl:RDS1326464 var_EffectiveDate map var_LifecycleActivity          
COOLING WATER INLET TEMPERATURE  K | C | F  The inlet temperature of any pump-related Cooling Water at the battery limit of the pump unit    

A

    var_Type IndirectPropertyOfClassOfStreamAtRelativeLocation hasStreamType N023C var_Locator N013 var_IndirectPropertyType rdl:RDS369674 valPropertyValue map(Z33:AA33) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity      
COOLING WATER MAX.RETURN TEMPERATURE  K | C | F  The return temperature of any pump-related Cooling Water at the battery limit of the pump unit    

A

    var_Type IndirectPropertyOfClassOfStreamAtRelativeLocation hasStreamType N023C var_Locator N013 var_IndirectPropertyType rdl:RDS400184 valPropertyValue map(AD33:AF33) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity      
COOLING WATER  DESIGN TEMPERATURE  K | C | F  The design temperature of any pump-related Cooling Water.    

A

    var_Type ClassOfIndividualHasIndirectPropertyWithValue hasPossessorType N023C var_IndirectPropertyType rdl:RDS360449 valPropertyValue map(AG33:AI33) var_Scale oneOfN9009 var_EffectiveDate map     var_LifecycleActivity      
COOLING WATER INLET PRESSURE  kPa(g) | psig  The inlet pressure of any pump-related Cooling Water.    

A

    var_Type IndirectPropertyOfClassOfStreamAtRelativeLocation hasStreamType N023C var_Locator N013 var_IndirectPropertyType rdl:RDS14302040 valPropertyValue map(Z34:AA34) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity      
COOLING WATER MAX. RETURN PRESSURE  kPa(g) | psig  The return pressure  of any pump-related Cooling Water.    

A

    var_Type IndirectPropertyOfClassOfStreamAtRelativeLocation hasStreamType N023C var_Locator N013 var_IndirectPropertyType rdl:RDS7344775 valPropertyValue map(AD34:AF34) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity      
COOLING WATER DESIGN PRESSURE  kPa(g) | psig  The maximum design pressure  of any pump-related Cooling Water.    

A

    var_Type ClassOfIndividualHasIndirectPropertyWithValue hasPossessorType N023C var_IndirectPropertyType rdl:RDS1470835011 valPropertyValue map(AG34:AI34) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
COOLING WATER SOURCE The source of any pump-related Cooling Water.    

A

    var_Type StreamHasSource hasStream N023 var_Source map(Y35:AE35) var_Defined id() var_CardinalityOfStream rdl:RDS222625 var_CardinalityOfSource rdl:RDS999900701 var_EffectiveDate map var_LifecycleActivity      
COOLING WATER CHLORIDE CONCENTRATION     ppm  The Chloride concentration of any pump-related Cooling Water.    

A

    var_Type ClassOfCompositionDefinitionWithConcentration hasClassOfWhole N023C var_ClassOfPart rdl:RDS2223483 var_Concentration map(AI36:AJ36) var_Scale rdl:RDS1333484 var_EffectiveDate map var_LifecycleActivity          
INSTRUMENT AIR MAXIMUM PRESSURE  kPa(g) | psig  The maximum pressure of any pump-related Instrument Air.    

A

    var_Type ClassOfIndividualHasIndirectPropertyWithValue hasPossessorType N024C var_IndirectPropertyType rdl:RDS7344775 valPropertyValue map(AC37:AD37) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
INSTRUMENT AIR MINIMUM PRESSURE  kPa(g) | psig  The minimum pressure of any pump-related Instrument Air.    

A

    var_Type ClassOfIndividualHasIndirectPropertyWithValue hasPossessorType N024C var_IndirectPropertyType rdl:RDS7344837 valPropertyValue map(AI37:AJ37) var_Scale oneOfN9011 var_EffectiveDate map var_LifecycleActivity          
STEAM FOR DRIVERS MAXIMUM TEMPERATURE  K | C | F  The maximum temperature of any pump driver related Steam supply.    

A

    var_Type ClassOfIndividualHasIndirectPropertyWithValue hasPossessorType N025C var_IndirectPropertyType rdl:RDS400184 valPropertyValue map(AB40:AD40) var_Scale oneOfN9009 var_EffectiveDate map var_LifecycleActivity          
STEAM FOR DRIVERS MINIMUM TEMPERATURE  K | C | F  The minimum temperature of any pump driver related Steam supply.    

A

    var_Type ClassOfIndividualHasIndirectPropertyWithValue hasPossessorType N025C var_IndirectPropertyType rdl:RDS400229 valPropertyValue